← Back to knowledge hub
RHEPANOL & PIB ROOFING · PILLAR PAGE

Rhepanol hfk: Specifications, Uses and Installation

Rhepanol hfk is FDT’s flexible PIB roofing membrane with fleece backing and a weldable edge. Reliable estimating starts with the exact sheet width, approved attachment method, substrate and detail design.

Professional roofers installing Rhepanol HFK roofing on a flat roof, using grey PIB roofing sheets and DakCalc for material calculation.

ROOF MEMBRANES · RHEPANOL (PIB)

Rhepanol hfk is FDT’s flexible PIB roofing membrane with fleece backing and a weldable edge. Reliable estimating starts with the exact sheet width, approved attachment method, substrate and detail design.

Quick answer

QRS lists grey hfk with nominal overall thickness 2.5 mm including 1 mm fleece, in 15 m rolls at 1.50, 1.00 and 0.50 m widths. Suitable FDT assemblies may use mechanical attachment, partial adhesive bonding or ballast. The membrane seams are hot-air welded.

Construction, thickness and roll formats

FDT describes hfk as 1.5 mm PIB waterproofing with a 1.0 mm fleece backing; QRS therefore lists an overall 2.5 mm including fleece. There is a designated hot-air welding edge. Check the exact product variant rather than assuming all hfk sheets are identical.

QRS lists grey rolls 15 m long at 1.50 m (22.5 m²), 1.00 m (15 m²) and 0.50 m (7.5 m²) widths. These are nominal areas, not the net yield after laps and cuts. See our roll estimator guide.

Mechanical attachment or partial bonding

FDT allows mechanically attached hfk within suitable system constructions, including overlap fastenings. The pattern and fixing specification depend on deck and wind actions. See mechanical fixing guidance.

Specific FDT products exist for partially bonded systems. Approval depends on the exact substrate and assembly, not just having an adhesive on site. See the adhesive and substrate guide.

Practical note

Only confirm the application method after checking the full build-up and current FDT system details.

Seams, upstands and roof details

Compatible hfk joints are made with hot air. Surfaces must be clean and dry; suitable cleaner and weld tests are used as instructed. Refer to the welding and detailing guide.

Outlets, flashings, upstands and roof edges require membrane-compatible FDT accessories and separate quantities. See estimating roof trims and roof outlets, without copying generic EPDM or PVC junction details.

Example: estimate an hfk roll order

Measure the roof and check how the selected width fits the layout. Allow for laps, cuts and separate upstand material. Our seam overlap article covers the estimating terms.

Select the exact hfk product in DakCalc to view provisional complete rolls, stock and rolls to buy. A contractor purchase €/m² rate can be converted to full-roll cost. Confirm against a real cutting plan before releasing the order.

Worked example

A 12 m² roof plus 10% provisional allowance suggests 13.2 m². A 1.50 × 15 m roll has nominal 22.5 m², so one roll may cover it if the true layout works.

Where product documentation controls

FDT/QRS publish specifications, approved constructions and detail guidance. Check current editions, membrane designation, wind zones, fire requirements, insulation and any retained roof.

Record installation, edge termination, welding, tests, safety and aftercare separately in the bill of materials and cost estimate.

DAKCALC

Estimate Rhepanol roof area, rolls and materials

Select PIB (Rhepanol), verify the hfk roll format and enter actual supplier purchase prices. DakCalc provides a provisional material estimate, not an approved laying plan, wind design or FDT system certification. Verify the delivered hg roll format and configuration.

Open the DakCalc calculator →

More Rhepanol guides

Also useful in the knowledge hub: roofing system comparison, calculating membrane laps, roof-edge trims and corners.

Frequently asked questions

What sizes are available for Rhepanol hfk?

QRS lists grey 1.50 × 15 m, 1.00 × 15 m and 0.50 × 15 m rolls, among formats to confirm at purchase.

Can hfk be bonded?

Yes, in FDT-approved partially bonded assemblies using the specified adhesive and compatible substrate.

Are hfk seams solvent welded?

FDT documents hot-air welded hfk seams. Do not assume solvent welding is suitable.

Sources and technical documents

  1. FDT · Rhepanol hfk: applications, construction and installation guides
  2. QRS · Leveringsvorm en rolafmetingen Rhepanol hfk
  3. QRS · Rhepanol hfk productinformatie
  4. QRS · Verwerkingsrichtlijnen en beschikbare downloads Rhepanol

Product dimensions, adhesives, fixing methods and examples do not certify a roof assembly. Check current FDT/QRS guidance, local rules, project-specific wind design and your supplier quote before ordering.

Note: this is general information, not a substitute for technical assessment or product-specific installation guidance.

Need a quick roof estimate?

Use DakCalc for indicative materials and project costs.

Open DakCalc ↗