FIRE SAFETY & ROOFING · 9 min

Fire-safe roof insulation: PIR, EPS and mineral wool compared

Insulation fire safety cannot be reduced to one board's reaction-to-fire class. PIR, EPS and mineral wool behave differently, but facings, membrane, deck, attachment and construction details also determine system performance.

FIRE SAFETY · FLAT ROOFS · DAKCALC KNOWLEDGE BASE

Insulation fire safety cannot be reduced to one board's reaction-to-fire class. PIR, EPS and mineral wool behave differently, but facings, membrane, deck, attachment and construction details also determine system performance.

Quick answer

Select insulation against both thermal and fire-performance requirements of the complete roof assembly. Do not assume that PIR is universally safe, EPS universally unsuitable or mineral wool a complete solution. Confirm the exact product and classified assembly before selecting installation methods.

PIR: distinguish board variants

PIR boards come with different facings. Aluminium, mineral-fibre and bitumen-faced products are not interchangeable simply because their core material is PIR.

Verify product-specific declarations and the approved combination of membrane, attachment and substrate. See flat roof insulation systems.

EPS: account for heat sensitivity

EPS is thermoplastic and can deform under heat. Open flame must not reach an unprotected board or edge not designed for that process. Any separation layer must be supported by the specified system.

Exposed insulation at upstands and edges is a particular construction-stage hazard. See junction safety.

Mineral wool does not classify the entire roof

Some stone-wool boards offer favourable reaction-to-fire properties, but actual roofing systems also include facings, adhesives, vapour layers, timber and membranes.

A favourable insulation Euroclass does not independently establish BROOF(t1) for the complete roof. Review roofing system fire performance.

Quantity planning must include junctions

Insulation thickness and taper affect edge heights, skylights and penetrations. Material quantities therefore need roof area, edges, board format and fixings rather than area alone.

Record these parts separately and verify moisture and fire design. Roof energy-saving calculations are useful but do not establish fire classification.

DAKCALC

Plan the roofing job

Record roof area, upstands, edges and selected materials in the calculator. A DakCalc estimate is not a fire-safety certificate, hot-work permit or approved roof detail.

Open calculator →

Flat roof fire-safety article library

Start with the central guide, then choose the detail relevant to your project.

Related DakCalc guides: Roofing work preparation · Safe working on flat roofs · Calculate bitumen roofing · Flat-roof junction details · PIR, EPS and tapered insulation · Compare roofing membranes · Flat roof renovation · Solar panels on flat roofs · Calculate roof energy savings.

Frequently asked questions

Is mineral wool always the safest roof?

Not automatically. Assess the whole assembly and its relevant declared fire performance.

Can bitumen be torched directly onto EPS?

Not onto unprotected EPS; a valid approved system and compatible application procedure are essential.

Does one product Euroclass prove BROOF(t1)?

No. The relevant roof classification concerns the tested assembly and its stated conditions.

Sources and technical guidance

Sources reviewed on 20 November 2026. Check current wording, project conditions and manufacturer specifications.

  1. NEN — NEN 6050:2009, brandveilig werken aan gesloten dakbedekkingssystemen
  2. VEBIDAK — Vakrichtlijn Gesloten Dakbedekkingssystemen 2025
  3. VEBIDAK — Vakrichtlijn 2025 (PDF)
  4. NEN — NEN 6063:2019, brandgevaarlijkheid van daken
  5. Verbond van Verzekeraars — Brandgevaarlijke werkzaamheden
  6. Brandweer Nederland — Het juiste blusmiddel
  7. SOPREMA — Brandpreventie op platte daken

Practical information, not permission to carry out hazardous work. Apply current Dutch standards, building rules, risk assessment, insurer conditions and manufacturer instructions; stop when the construction or risk is unknown.