Cracks in bitumen membranes can reflect movement, weathering or stress at joints. A suitable repair addresses the underlying condition as well as restoring the waterproofing.

FLAT ROOFS · REPAIR & LEAKS

Cracks in bitumen membranes can reflect movement, weathering or stress at joints. A suitable repair addresses the underlying condition as well as restoring the waterproofing.

Quick answer

Measure crack length and inspect the surrounding membrane and any structural movement. Choose a compatible repair strip and consider a movement-relief strip where required by the system.

Map the crack

Record length, width, orientation and whether the defect follows a joint, movement detail, corner or edge.

Inspect whether adjacent waterproofing remains securely bonded or whether repeated movement is present.

Choose a method appropriate to movement

Bonding a rigid patch over a moving joint may reproduce the defect. The Dutch guideline allows for an appropriate separation or expansion strip.

Prepare the existing surface and specify compatibility, bond and lap details for the actual membrane system.

Estimate strips and labour

Use the repair strip length and width, end connections, offcuts and any additional separation piece, not just the tiny opening visible.

For illustration, a 3 m crack repaired using a hypothetical 0.4 m-wide strip represents 1.2 m² before end laps and cutting waste.

Important

Example strip width is not a technical prescription.

Check adjacent roof construction

Persistent movement or brittle surrounding membrane can make a local repair ineffective unless the cause is addressed.

Record the agreed solution and review overlay versus replacement for extensive degradation.

DAKCALC

From roof inspection to a clear job record

Record the job, materials and labour; verify the repair specification and costs before work starts.

Explore DakCalc →

More flat roof repair guides

For roof material calculations: the DakCalc technical guide.

Frequently asked questions

Can cracks simply be torched closed?

Not without checking causes, fire safety and system suitability.

What is an expansion strip?

A detail used where needed to accommodate or isolate movement.

How is membrane consumption measured?

From complete repair strip dimensions, laps and actual roll ordering quantities.