Calculate PIR Insulation Thickness for Flat Roofs
Appropriate PIR thickness depends on declared material performance, required whole-roof Rc and space at thresholds, roof edges, outlets and upstands. A thickness satisfying one grant criterion may not satisfy all other
ROOF INSULATION · SUBSIDIES, BBL & ENERGY
Appropriate PIR thickness depends on declared material performance, required whole-roof Rc and space at thresholds, roof edges, outlets and upstands. A thickness satisfying one grant criterion may not satisfy all other requirements.
For homogeneous PIR material, theoretical thickness d = target Rd × λ. Then choose an actual manufacturer product and verify full Rc, height limits, tapered insulation, vapour control and fixings.
Select target and actual material
Determine whether the goal is ISDE product Rd, legal building Rc or stronger energy performance. Use the specified board's declared conductivity and resistance.
Rd versus Rc explains the distinction.
Check the thickness formula
At hypothetical λ = 0.024 and target Rd 3.5, thickness d = 3.5 × 0.024 = 0.084 m or 84 mm.
This is arithmetic only: actual supply thickness, product values and programme eligibility must be confirmed.
Rd 3.5 × 0.024 W/(m·K) = 0.084 m = 84 mm.
Check heights and roof build-up
Additional boards can affect door thresholds, drains, flashings, trims and rooflights. Verify tapered layers, moisture control, loading and fixings.
See tapered insulation and renovation planning.
Quantify and order boards
Schedule flat and tapered boards separately and account for cutting, formats and supplier packs. Tapered boards do not have one thickness throughout.
See the materials schedule for stock versus purchasing.
From roof measurements to a traceable estimate
Use DakCalc’s existing material, quantity and cost workflows. Subsidy eligibility, statutory Rc compliance and energy savings are not automatically certified.
Open calculator →More insulation guides
Additional technical reading: PIR, EPS and tapered insulation · roof renovation.
Frequently asked questions
Is 80 mm PIR always enough for ISDE?
No. Actual declared Rd and other product requirements govern.
Does d/lambda calculate roof Rc?
No. It estimates homogeneous material Rd.
Will thicker boards affect edge trims?
Possibly. Check junction heights and drainage.
Official sources (check for updates)
Content reviewed 13 November 2026. This information is not regulatory or engineering approval. Rates and rules can change; verify eligibility, evidence, moisture safety and structural suitability per project.