Calculate Heat Loss Through a Flat Roof
Heat loss through a flat roof depends on the whole-assembly U-value, area and temperature difference. A simple heat-transfer estimate is useful for understanding but not a full building-energy assessment.
ROOF INSULATION · SUBSIDIES, BBL & ENERGY
Heat loss through a flat roof depends on the whole-assembly U-value, area and temperature difference. A simple heat-transfer estimate is useful for understanding but not a full building-energy assessment.
For steady-state transmission use Q = U × A × ΔT in watts. Compare pre- and post-insulation U for indicative savings; annual values need weather, degree days and building system data.
Use whole-roof U and area
A lower U-value means less heat flow. Use assembly U, not a value derived from insulation product Rd alone.
Rd and Rc have different meanings.
Calculate instantaneous heat flow
Assume 40 m², U = 0.30 W/(m²K) and 20 K difference. Q = 0.30 × 40 × 20 = 240 W.
This is heat loss at that moment under the assumed steady-state conditions, not an annual energy figure.
0.30 × 40 × 20 = 240 watts.
Compare before and after
If an old U of 1.0 becomes 0.30 on 40 m², the modelled instantaneous reduction at 20 K is (1.0 − 0.30) × 40 × 20 = 560 W.
Actual conditions vary by climate, occupation and the rest of the building.
Estimate annual loss with disclosed assumptions
Heating degree days can approximate seasonal conductive heat flow; boiler efficiency, heat pump COP, ventilation and gains require additional modelling.
From roof measurements to a traceable estimate
Use DakCalc’s existing material, quantity and cost workflows. Subsidy eligibility, statutory Rc compliance and energy savings are not automatically certified.
Open calculator →More insulation guides
Additional technical reading: PIR, EPS and tapered insulation · roof renovation.
Frequently asked questions
How much heat does a 40 m² roof lose?
It depends on U and temperature difference; an example is 240 W at U 0.30 and ΔT 20 K.
Does 240 W mean annual use?
No. Power in watts differs from energy in kWh.
Can U be calculated from PIR alone?
Not reliably for the whole construction without other layers and corrections.
Official sources (check for updates)
Content reviewed 13 November 2026. This information is not regulatory or engineering approval. Rates and rules can change; verify eligibility, evidence, moisture safety and structural suitability per project.